7 × 6 TB in RAID 6

Usable space, rebuild time and read error risk for 7 drives of 6 TB each.

7 × 6 TB drives in RAID 6 give 30 TB of usable space, which Windows shows as 27.3 TB. 12 TB goes to parity, so 71% of the 42 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
30TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing7 × 6 TB in RAID 6
Raw42 TB
Efficiency71%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

7 drives of 6 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
42 TB
100%
None
—
—
6 TB
14%
Any 6
11 h
Fixed by another copy
36 TB
86%
Any 1
11 h
25%
30 TB
71%
Any 2
11 h
Fixed by parity
RAID 10 +1 spare
18 TB
43%
1 to 3
11 h
4.7%
RAID 50 +1 spare
24 TB
57%
1 to 2
11 h
9.2%
Needs at least 8 drives

7 × 6 TB in RAID 6: the numbers

Usable space30 TB (27.3 TB in Windows)
Raw space42 TB
Used for protection12 TB
Efficiency71%
Drives that can failAny 2
Rebuild at 150 MB/s11 h
Rebuild at 50 MB/s (busy)33 h
Data read during rebuild36 TB
Read error risk, desktop drives94% (corrected)
Read error risk, NAS drives25% (corrected)

Rebuild

Replacing a failed drive means writing a full 6 TB drive. At 150 MB/s with no other load that takes about 11 h; on a busy array running at 50 MB/s, about 33 h. The rebuild reads every surviving drive: 36 TB in total.

Read errors

Reading 36 TB, the chance of at least one unreadable sector is 94% with desktop drives (1 per 1014 bits) and 25% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

For 6 TB drives this is the setup most administrators would choose: the rebuild takes 11 h, and the array stays protected the whole time.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240