4 × 14 TB in RAID 6

Usable space, rebuild time and read error risk for 4 drives of 14 TB each.

4 × 14 TB drives in RAID 6 give 28 TB of usable space, which Windows shows as 25.5 TB. 28 TB goes to parity, so 50% of the 56 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
28TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 14 TB in RAID 6
Raw56 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 14 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
56 TB
100%
None
—
—
14 TB
25%
Any 3
25 h
Fixed by another copy
42 TB
75%
Any 1
25 h
29%
28 TB
50%
Any 2
25 h
Fixed by parity
28 TB
50%
1 to 2
25 h
11%
Needs at least 6 drives
Needs at least 8 drives

4 × 14 TB in RAID 6: the numbers

Usable space28 TB (25.5 TB in Windows)
Raw space56 TB
Used for protection28 TB
Efficiency50%
Drives that can failAny 2
Rebuild at 150 MB/s25 h
Rebuild at 50 MB/s (busy)3.2 days
Data read during rebuild42 TB
Read error risk, desktop drives97% (corrected)
Read error risk, NAS drives29% (corrected)

Rebuild

Replacing a failed drive means writing a full 14 TB drive. At 150 MB/s with no other load that takes about 25 h; on a busy array running at 50 MB/s, about 3.2 days. The rebuild reads every surviving drive: 42 TB in total.

Read errors

Reading 42 TB, the chance of at least one unreadable sector is 97% with desktop drives (1 per 1014 bits) and 29% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

With four drives, RAID 6 and RAID 10 both give 28 TB. RAID 6 survives any two failures; RAID 10 writes and rebuilds faster. For 14 TB drives this is the setup most administrators would choose: the rebuild takes 25 h, and the array stays protected the whole time.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240