6 × 4 TB in RAID 6

Usable space, rebuild time and read error risk for 6 drives of 4 TB each.

6 × 4 TB drives in RAID 6 give 16 TB of usable space, which Windows shows as 14.6 TB. 8 TB goes to parity, so 67% of the 24 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
16TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing6 × 4 TB in RAID 6
Raw24 TB
Efficiency67%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

6 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
24 TB
100%
None
—
—
4 TB
17%
Any 5
7 h 24 min
Fixed by another copy
20 TB
83%
Any 1
7 h 24 min
15%
16 TB
67%
Any 2
7 h 24 min
Fixed by parity
12 TB
50%
1 to 3
7 h 24 min
3.1%
16 TB
67%
1 to 2
7 h 24 min
6.2%
Needs at least 8 drives

6 × 4 TB in RAID 6: the numbers

Usable space16 TB (14.6 TB in Windows)
Raw space24 TB
Used for protection8 TB
Efficiency67%
Drives that can failAny 2
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild20 TB
Read error risk, desktop drives80% (corrected)
Read error risk, NAS drives15% (corrected)

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. The rebuild reads every surviving drive: 20 TB in total.

Read errors

Reading 20 TB, the chance of at least one unreadable sector is 80% with desktop drives (1 per 1014 bits) and 15% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

With 4 TB drives, RAID 5 would give 20 TB with a rebuild of 7 h 24 min. RAID 6 is still the safer choice for data you cannot replace.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240