7 × 4 TB in RAID 5

Usable space, rebuild time and read error risk for 7 drives of 4 TB each.

7 × 4 TB drives in RAID 5 give 24 TB of usable space, which Windows shows as 21.8 TB. 4 TB goes to parity, so 86% of the 28 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
24TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing7 × 4 TB in RAID 5
Raw28 TB
Efficiency86%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

7 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
28 TB
100%
None
—
—
4 TB
14%
Any 6
7 h 24 min
Fixed by another copy
24 TB
86%
Any 1
7 h 24 min
17%
20 TB
71%
Any 2
7 h 24 min
Fixed by parity
RAID 10 +1 spare
12 TB
43%
1 to 3
7 h 24 min
3.1%
RAID 50 +1 spare
16 TB
57%
1 to 2
7 h 24 min
6.2%
Needs at least 8 drives

7 × 4 TB in RAID 5: the numbers

Usable space24 TB (21.8 TB in Windows)
Raw space28 TB
Used for protection4 TB
Efficiency86%
Drives that can failAny 1
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild24 TB
Read error risk, desktop drives85%
Read error risk, NAS drives17%

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. The rebuild reads every surviving drive: 24 TB in total.

Read errors

Reading 24 TB, the chance of at least one unreadable sector is 85% with desktop drives (1 per 1014 bits) and 17% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 7 drives sharing one parity, a second failure during the rebuild gets more likely. RAID 6 gives 20 TB with two-drive protection.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168