7 × 24 TB in RAID 5

Usable space, rebuild time and read error risk for 7 drives of 24 TB each.

7 × 24 TB drives in RAID 5 give 144 TB of usable space, which Windows shows as 131 TB. 24 TB goes to parity, so 86% of the 168 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
144TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing7 × 24 TB in RAID 5
Raw168 TB
Efficiency86%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

7 drives of 24 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
168 TB
100%
None
—
—
24 TB
14%
Any 6
44 h
Fixed by another copy
144 TB
86%
Any 1
44 h
68%
120 TB
71%
Any 2
44 h
Fixed by parity
RAID 10 +1 spare
72 TB
43%
1 to 3
44 h
17%
RAID 50 +1 spare
96 TB
57%
1 to 2
44 h
32%
Needs at least 8 drives

7 × 24 TB in RAID 5: the numbers

Usable space144 TB (131 TB in Windows)
Raw space168 TB
Used for protection24 TB
Efficiency86%
Drives that can failAny 1
Rebuild at 150 MB/s44 h
Rebuild at 50 MB/s (busy)5.6 days
Data read during rebuild144 TB
Read error risk, desktop drivesover 99%
Read error risk, NAS drives68%

Rebuild

Replacing a failed drive means writing a full 24 TB drive. At 150 MB/s with no other load that takes about 44 h; on a busy array running at 50 MB/s, about 5.6 days. The rebuild reads every surviving drive: 144 TB in total.

Read errors

Reading 144 TB, the chance of at least one unreadable sector is over 99% with desktop drives (1 per 1014 bits) and 68% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 24 TB drives we would pick RAID 6. 8 drives in RAID 6 give the same 144 TB and survive two failures, or a read error during a rebuild. Keeping 7 drives, RAID 6 gives 120 TB.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168