3 × 2 TB in RAID 5

Usable space, rebuild time and read error risk for 3 drives of 2 TB each.

3 × 2 TB drives in RAID 5 give 4 TB of usable space, which Windows shows as 3.6 TB. 2 TB goes to parity, so 67% of the 6 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
4TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing3 × 2 TB in RAID 5
Raw6 TB
Efficiency67%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

3 drives of 2 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
6 TB
100%
None
—
—
2 TB
33%
Any 2
3 h 42 min
Fixed by another copy
4 TB
67%
Any 1
3 h 42 min
3.1%
Needs at least 4 drives
Needs at least 4 drives
Needs at least 6 drives
Needs at least 8 drives

3 × 2 TB in RAID 5: the numbers

Usable space4 TB (3.6 TB in Windows)
Raw space6 TB
Used for protection2 TB
Efficiency67%
Drives that can failAny 1
Rebuild at 150 MB/s3 h 42 min
Rebuild at 50 MB/s (busy)11 h
Data read during rebuild4 TB
Read error risk, desktop drives27%
Read error risk, NAS drives3.1%

Rebuild

Replacing a failed drive means writing a full 2 TB drive. At 150 MB/s with no other load that takes about 3 h 42 min; on a busy array running at 50 MB/s, about 11 h. The rebuild reads every surviving drive: 4 TB in total.

Read errors

Reading 4 TB, the chance of at least one unreadable sector is 27% with desktop drives (1 per 1014 bits) and 3.1% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 2 TB drives the rebuild is short enough that RAID 5 is a reasonable choice, as long as anything you cannot replace is also backed up elsewhere.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168