2 × 16 TB in RAID 1

Usable space, rebuild time and read error risk for 2 drives of 16 TB each.

2 × 16 TB drives in RAID 1 give 16 TB of usable space, which Windows shows as 14.6 TB. 16 TB goes to mirror copies, so 50% of the 32 TB raw space is usable. Both drives hold the same data, so the array survives one failed drive.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
16TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing2 × 16 TB in RAID 1
Raw32 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

2 drives of 16 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
32 TB
100%
None
—
—
16 TB
50%
Any 1
29 h
12%
Needs at least 3 drives
Needs at least 4 drives
Needs at least 4 drives
Needs at least 6 drives
Needs at least 8 drives

2 × 16 TB in RAID 1: the numbers

Usable space16 TB (14.6 TB in Windows)
Raw space32 TB
Used for protection16 TB
Efficiency50%
Drives that can failAny 1
Rebuild at 150 MB/s29 h
Rebuild at 50 MB/s (busy)3.7 days
Data read during rebuild16 TB
Read error risk, desktop drives72%
Read error risk, NAS drives12%

Rebuild

Replacing a failed drive means writing a full 16 TB drive. At 150 MB/s with no other load that takes about 29 h; on a busy array running at 50 MB/s, about 3.7 days. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 16 TB, the chance of at least one unreadable sector is 72% with desktop drives (1 per 1014 bits) and 12% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

A mirror is the simplest safe setup for two drives. During a rebuild the remaining drive is the only copy, so with 16 TB drives keep a separate backup current. If you add drives later, three 16 TB drives in RAID 5 would give 32 TB, and four in RAID 6 32 TB with two-drive protection.

Similar setups

All RAID 1 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB